AC SPECIFICATIONS Protect or Disconnect Circuitry Yes Thermal Fusing Yes Catastrophic Surge Circuit Yes Single Pulse Energy Dissipation 2325 Joules Spike Capacity 91,000A EMI/RFI Noise Filtration 60dB-100dB Line Voltage 120VAC, 50/60 Hz Clamping Level (TVSS Voltage) 330V Initial Clamping Level 141V RMS/200V Peak Overvoltage Shutoff 134VAC Undervoltage Shutoff 95VAC Protection Modes L-N, N-G, L-G Maximum Current Rating 15A (1800W) Response Time <1ns
TELCO SPECIFICATIONS SignalPerfect Circuitry Yes Fuseless / Auto Resettable Yes Clamping Level 260v Capacitance 30pf (approx.) Suppression Modes Metallic & Longitudinal Wires Protected 1 pair, (4,5) Connectors RJ-11/45
COAX SPECIFICATIONS Antenna/Cable Lines Protected 1 Antenna/Cable Clamping 0.7v Antenna/Cable Attenuation (5MHz-950MHz) <1dB Satellite Lines Protected 2 Satellite Clamping 27v Satellite Attenuation (950MHz-2.20GHz) <1dB Coax Connectors Female
PRODUCT FEATURES Number of Outlets 11 Always On Outlets up to 9 Switched Outlets up to 4 Delayed Outlets up to 6 Cord Length 10 ft. Connections Straight Length 12" Width 17" Height 3.5" Weight 30 lbs.
|